DURASTILL uses filtering
for clean, refreshing, healthy and
economical drinking water for your family.
Kansas
City Testing Laboratory
| This is a breakdown of the test results
performed on the Durastill Distiller's Model 30H, 30J and 46C. |
| Test subject |
Amount spiked ppm |
EPA limit ppm |
Times EPA limit spiked |
30A
ppm
|
30J
ppm
|
46C
ppm
|
% Removed |
Silver
Arsenic
cadmium
Lead
Selenium
Fluoride |
4.0
4.0
4.0
4.0
4.0
1.6 |
0.05
0.05
0.01
0.05
0.01
* |
80
80
400
80
400
* |
<0.024
<0.006
<0.01
<0.05
<0.01
<0.04 |
<0.024
<0.006
<0.01
<0.05
<0.01
<0.04 |
<0.024
<0.006
<0.01
<0.05
<0.01
<0.04 |
>99.4
>99.8
>99.5
>98.7
>99.7
>97.5 |
|
Results shown below are with Distiller/filter system. |
| 2,4-D |
0.200 |
.100 |
2 |
<0.009 |
<0.008 |
<0.007 |
>95.5 |
| Silvex |
0.210 |
0.010 |
21 |
<0.003 |
<0.002 |
<0.002 |
>98.6 |
| Lindane |
0.531 |
0.004 |
132 |
<0.0002 |
<0.0002 |
<0.0002 |
>99.6 |
| Endrine |
0.155 |
<0.0002 |
775 |
<0.0002 |
<0.0002 |
<0.0002 |
>99.8 |
| Methoxychlr |
0.530 |
0.100 |
5.3 |
<0.002 |
<0.002 |
<0.002 |
>99.6 |
| THM |
66.7 |
0.100 |
667 |
<0.10 |
<0.10 |
<0.10 |
>99.2 |
| Benzene |
0.50 |
#. |
#. |
<0.015 |
<0.015 |
<0.015 |
>97. |
| TCE |
1.00 |
#. |
#. |
<0.043 |
<0.043 |
<0.043 |
>95.7 |
< Less than (below detectible limit stated)
> Greater than
* Standards vary according to average maximum daily air temperature
# No EPA Standards
% Removed are shown as worst case for line entry |
| Test results performed on the Durastill distiller's
Model 30H, 30J, and 46C |
| Test subject |
Amount spiked ppm |
30H
ppm
|
30J
ppm
|
46C
ppm
|
% Removed |
| Iron |
31.8 |
<0.06 |
<0.06 |
<0.06 |
99.8 |
| Copper |
9.99 |
<0.03 |
<0.03 |
<0.03 |
99.7 |
| Zinc |
10.5 |
<0.01 |
<0.01 |
<0.01 |
99.6 |
| Mercury |
1.38 |
<0.001 |
<0.001 |
<0.001 |
>99.9 |
| Barium |
7.27 |
<0.01 |
<0.01 |
<0.01 |
99.9 |
| Chlorine |
12.4 |
<0.10 |
<0.10 |
<0.10 |
99.0 |
| Sulfide |
18.2 |
<0.40 |
<0.40 |
<0.80 |
95.6 |
| Sulfate |
105.4 |
<2.00 |
2.30 |
3.20 |
97 |
| Nitrate |
19.3 |
<0.18 |
<0.18 |
<0.18 |
>99.0 |
| PCB: Aroclor 1016 |
0.31 |
<0.0004 |
<0.0004 |
<0.0004 |
>99.9 |
| PCB: Aroclor 1260 |
4.60 |
<0.001 |
<0.001 |
<0.001 |
>99.9 |
| Aldicarb (Sulfone) |
7.98 |
<0.020 |
<0.020 |
<0.020 |
>99.7 |
| Ammonia |
100 |
<0.20 |
<0.20 |
<0.20 |
>99.8 |
| EDB |
27.2 |
<0.01 |
<0.01 |
<0.01 |
>99.9 |
| Sodium |
129.5 |
1.62 |
3.33 |
2.78 |
97.4 |
| Calcium |
107 |
2.46 |
3.00 |
2.27 |
97.2 |
< Less than (below detectible limit stated)
> Greater than
% Removed are shown as worst case for line entry
Results shown are with the Distiller/filter system |
|
Electric Water Distiller
131 Leas Park Place
Climax Springs, MO 65324
Phone (573) 347-9868 or
toll free 1-800-854-8365
Fax (573) 347-3611